en:hydro:emma
This is an old revision of the document!
EMMA
$$\frac{Q_E}{Q_P} = \frac{c_P-c_F}{c_F-c_E}$$
E steht für Event und P für Pre-Event und F für Fluss (Mischung).
qp = 1 cp = -5.44 # permil, matrix cf = -6.33 # permil ground water, mixing ce = -7.91 # permil, event or macropore flow qe = qp*(cp-cf)/(cf-ce) s = qe+qp pqe = qe/s pqe
/usr/www/users/uhydro/doku/data/attic/en/hydro/emma.1697720214.txt.gz · Last modified: 2024/04/10 10:14 (external edit)